136 www.controltechniques.com SM-EZMotion Module User Guide
Examples:
x.48 = 11023 would signify that user programs are
currently running on Task 2 and Task 1, and that a Index is
running on Profile 1 while a Jog is running on Profile 0.
x.48 = 104 would signify that a user program is running on
Task 0 and Gearing motion is running on Profile 0.
x.50 – Option Module Error Status
The error status is provided so that only one option module
error trip is required for each option module slot. If an error
occurs, the error code is written to this parameter, and the
drive may produce a SLx.Er trip (where x is the slot
number). A value of zero indicates that the module has not
detected an error. A non-zero value indicates that an error
has been detected (See Errors and Error Codes in
Diagnostics section of this manual). When the drive is
reset, this parameter is cleared for the relevant option
module.
All parameters between x.00 through x.50 not listed above
are not used by the SM-EZMotion module.