Emerson Fisher 1061 Manual de instalación Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
Instruction Manual
D100325X012
1061 H & J Actuator
October 2012
8
Figure 2. Fisher 1061 Mounting Dimensions (Continued)
HMOUNTING
(1)
Actuator Size
S(Actuator
Output Shaft
Diameter)
V L K T U W
mm
30 22.2 26.2 19.1
15.75
15.62
57.2 28.4 5/16-18 UNC
30, 40, 60,
&68
28.6 26.2 19.1
22.10
21.97
76.2 38.1 3/8-16 UNC
38.1 38.1 28.4
28.45
28.32
88.9 44.5 1/2-13 UNC
40, 60, & 68
44.5 x 50.8 122.9 69.9
44.45
44.50
88.9 44.5 1/2-13 UNC
50.8 122.9 69.9
50.83
50.90
88.9 44.5 1/2-13 UNC
Inches
30 7/8 1.03 0.75
0.620
0.615
2.25 1.12 5/16-18 UNC
30, 40, 60,
&68
1-1/8 1.03 0.75
0.870
0.865
3.00 1.50 3/8-16 UNC
1-1/2 1.50 1.12
1.120
1.115
3.50 1.75 1/2-13 UNC
40, 60, & 68
1-3/4 X 2 4.84 2.75
1.750
1.752
3.50 1.75 1/2-13 UNC
2 4.84 2.75
2.001
2.004
3.50 1.75 1/2-13 UNC
1. Tolerance for the K dimension is indicated by showing maximum and minimum dimensions.
22.2 THRU 38.1 mm
(7/8 THRU 1-1/2 INCH) OUTPUT
SHAFTS WITH H MOUNTING
A3247-1
44.5 & 50.8 mm
(1-3/4 & 2 INCH)
KEYED E QUIPMENT SHAFTS WITH H MOUNTING
19A1462-C
19A1462-C
T
T
U
U
W(DIA)
W(DIA)
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 23 24

Comentarios a estos manuales

Sin comentarios