Instruction Manual
D100325X012
1061 H & J Actuator
October 2012
21
Figure 6. Fisher 1061 Actuator with Typical H and J Mounting Adaptations
52A9796-G
59A2412-A
B1856
NOTES:
1. KEYS 4, 5, AND 6 NOT REQUIRED FOR SIZE 60 ACTUATOR.
2. KEY 15 REQUIRED FOR 60-DEGREE ROTATION ONLY.
3. KEY 91 - APPLY ANTI-SEIZE SEALANT.
4.KEY92-APPLYTHREADLOCKINGADHESIVE(MEDIUM
STRENGTH).
5. KEY 93 - APPLY LITHIUM GREASE.
STEEL ACCESS PLATE (KEY 72) USED
ON ALUMINUM HOUSING CONSTRUCTIONS
Key 98* Woodruff Key for Actuator with H Mounting Adaptation, Alloy Steel
ACTUATOR
SIZE
KEYED SHAFT COUPLING DIAMETER
WOODRUFF
KEY NUMBER
PART NUMBER
mm Inches
40, 60, & 68
44.5 1-3/4 1211 F1358231252
50.8 2 1022-1 F1366131252
Key 98* Woodruff Key for Actuator with J Mounting Adaptation, Alloy S teel
ACTUATOR
SIZE
KEYED SHAFT COUPLING DIAMETER
WOODRUFF
KEY NUMBER
PART NUMBER
mm Inches
30
9.5 3/8 304 F1357631252
12.7 1/2 304 F1357631252
15.9 5/8 404 F1357731252
30, 40, 60, & 68
19.1 3/4 406 F1357831252
25.4 1 607 F1357931252
40, 60, & 68
31.8 1-1/4 809 F1358031252
38.1 1-1/2 811 F1358131252
*Recommended spare parts
Comentarios a estos manuales