Instruction Manual
D100325X012
1061 H & J Actuator
October 2012
4
Table 3. Acceptable Shaft Diameters and Torque Limits for Actuators with J Mounting
ACTUATOR
SIZE
COUPLING AVAILABILITY BY KEYED SHAFT DIAMETER TORQUE LIMIT FOR J MOUNTING
mm Inches NSm LbfSin
30
9.5
12.7
15.9
19.1
25.4
3/8
1/2
5/8
3/4
1
52
69
114
207
468
460
610
1010
1830
4140
40, 60, & 68
19.1
25.4
31.8
38.1
3/4
1
1-1/4
1-1/2
207
468
1030
1360
1830
4140
9110
12,000
Table 4. Approximate Actuator Weights
ACTUATOR
SIZE
ALUMINUM HOUSING CONSTRUCTION CAST IRON HOUSING CONSTRUCTION
kg Pounds kg Pounds
30 18 39 22 49
40 23 50 29 63
60 33 73 39 86
68 50 110 56 123
Actuator Mounting
Use the following steps to connect the actuator to a valve or other equipm ent. Unless otherwise specified, key
numbers are shown in figure 6.
WARNING
Perform the steps in the WARNING at the beginning of the Maintenance section.
Note
For an actuator with an H mounting adaptation and a 22.2 through 38.1 mm (7/8 through 1-1/2 inch) output shaft, find
dimensions and center of gravity information in figures 2 and 3, and approximate weights in table 4. This information is required
for proper fabrication of the user-provided bracket and coupling.
1. For an actuator with an H mounting adaptation, attach an appropriate mounting bracket (not provided) to the
mounting plate (key 23) with the cap screws (key 87). See figure 2 for mounting dimensions on the mounting plate.
2. Consult figure 4 for available mounting styles and positions. The actuator is normally positioned vertically with the
valve or other equipment in a horizontal pipeline.
Note
If the milled flats or the coupling on the end of the actuator output shaft (key 94) are oriented such that the output shaft cannot
accommodate the operated equipment shaft, refer to the Changing Positions portion of the Changing Actuator Mounting section.
This procedure describes how the output shaft can be repositioned to accommodate the operated equipment shaft.
3. If using an actuator with a J mounting adaptation, note that the valve shaft coupling (key 97) is furnished with two
keyways lettered A & B as shown in figure 5 (letters C and D on the coupling are not used and can be disregarded).
Comentarios a estos manuales