6
All Modules
ENVIRONMENTAL
Operating Non-operating
Temperature: 0° C to +55° C
(inlet air temp.
with forced air
cooling*)
–40° C to +85° C
Humidity (NC): 5% to 90% 5% to 90%
Vibration: 1 G sinusoidal,
5–100 Hz
2 axes horizontal
and vertical
(NEBS1)
*Note: Reference cooling requirements section of the user’s manual.
DEMONSTRATED MTBF
Predicted MTBF 207,058 hours, calculated using
Bellcore Standard: Issue 6, Method 1, Case 3
ELECTROMAGNETIC COMPATIBILITY (EMC)
Intended for use in systems meeting the following
regulations:
U.S.: FCC Part 15, Subpart B, Class A (non-residential)
c
Canada: ICES-003, Class A (non-residential) c
Emerson board products are tested in a representative
system to the following standards, results pending:
CE Mark per European EMC Directive 89/336/EEC c
with Amendments; Emissions: EN55022 Class B;
Immunity: EN55024
SAFETY
All printed wiring boards (PWBs) are manufactured
with a ammability rating of 94V-0 by UL recognized
manufacturers.