“c” Stall Foldback display
Search for
causes of
Increased
Load
Return Load to
Original
Size/Value
Return to
Normal
Operation
Yes
Incorrect
Motor Selected
for
Configuration
Yes
Download
Known Good
Application
Return to
Normal Operation
Contact
Technical Support
for Assistance
Determine
potential
causes
for mismatch
High Inertia
mismatch
Excessive Load
RST Motor
Phases Incorrectly
Wired
Wire
Correctly
per diagram
Download
Known Good
Application
Reutrn to
Normal Operation
Tuning
Parameters
not Optimal
No
No
No
Use Emersize
program to
determine
correct
motor/drive
match
Yes
Yes
No
Select Correct
Motor from
Setup View
or Motor Tab
"c" Fault
Stall Foldback
See
Appendix A
For
Correct Wiring
for Eb/Ei/En
Refer to
Tuning
Procedure in
Epsilon E Series
Reference Manual
Yes
Download
Known Good
Application
Reutrn to
Normal Operation
End