Product Data Sheet
00813-0100-4811, Rev DA
Catalog 2008 - 2009
Level-15
Rosemount 3300 Series
Mechanical, continued
Material Exposed to Tank Atmosphere • 316 / 316L SST (EN 1.4404), PTFE, PFA
(1)
and O-ring materials (model code 1) or
• Hastelloy
®
C-276 (UNS N10276), PTFE, PFA
(1)
and O-ring materials (model code 2) or
• Monel
®
400 (UNS N04400), PTFE, PFA
(1)
and O-ring materials (model code 3)
• PTFE
(2)
(model code 7) or
• PTFE
(2)
, 316 L SST (EN 1.4404) and O-ring materials (model code 8)
• 316L SST (EN 1.4404), Ceramic (Al
2
O
3
), Graphite (HTHP Probe, model code H)
• 316L SST (EN 1.4404), Ceramic (Al
2
O
3
), Graphite, PFA (HP Probe, model code P)
See “Ordering Information” on page 28.
Dimensions See “Dimensional Drawings” on page 19.
Probe Angle 0 to 90 degrees.
Housing / Enclosure Polyurethane-covered Aluminum or SST Grade CF8M (ASTM A743).
Flanges, Threads See “Tank Connection” on page 6 and “Ordering Information” on page 28.
Height Above Flange See “Dimensional Drawings” on page 19.
Weight Transmitter Head (TH): 5.5 lbs (2.5 kg) in Aluminum, 11 lbs (5 kg) in SST.
Flange: according to drawing 9150 077-601.
Coaxial probe: 0.67 lbs/ft (1 kg/m).
Rigid Single Lead probe: 0.25 lbs/ft (0.4 kg/m).
Rigid Twin Lead probe: 0.40 lbs/ft (0.6 kg/m).
Flexible Single Lead probe: 0.05 lbs/ft (0.07 kg/m).
Flexible Twin Lead probe: 0.09 lbs/ft (0.14 kg/m).
End weight: 0.88 lbs (0.40 kg) for single probes, 1.3 lbs (0.60 kg) for twin probes.
Environment
Ambient Temperature -40°F to +185°F ( -40°C to +85°C). LCD readable in: -4°F to +185°F (-20°C to +85°C).
Storage Temperature -40°F to +176°F ( -40°C to +80°C )
Process Temperature
(3)
Standard: -40°F to +302°F ( -40°C to +150°C )
HTHP: -76°F to +752°F ( -60°C to +400°C )
HP: -76°F to +392°F ( -60°C to +200°C )
See temperature and pressure diagrams on page Level-6.
Process Pressure
(3)
Standard: Full vacuum to 580 psig ( -1 to 40 Bar ).
HTHP: Full vacuum to 5000 psig (-1 to 345 Bar).
HP: Full vacuum to 5000 psig (-1 to 345 Bar).
See temperature and pressure diagrams on page Level-6.
Humidity 0 - 100% Relative Humidity.
Ingress Protection NEMA 4X, IP 66.
Telecommunication (FCC and R&TTE) FCC part 15 (1998) subpart B and R&TTE (EU directive 99/5/EC). Considered to be an
unintentional radiator under the Part 15 rules.
Factory Sealed Yes.
Vibration Resistance Polyurethane-covered aluminum housing: IEC 60770-1. Stainless steel housing: IACS E10.
Electromagnetic Compatibility Emission and Immunity: Meets EN 61326-1 (1997) and amendment A1, class A equipment
intended for use in industrial locations if installed in metallic vessels or still-pipes.
When rigid / flexible single and twin lead probes are installed in non-metallic or open vessels,
influence of strong electromagnetic fields might affect measurements.
Built-in Lightning Protection Meets EN 61000-4-4 Severity Level 4 and EN 61000-4-5 Severity Level 4.
Pressure Equipment Directive (PED) Complies with 97/23/EC article 3.3.
Measuring Performance
Reference Accuracy ± 0.2 in. (5 mm) for probes < 16.4 ft (5 m).
± 0.1% of measured distance for probes > 16.4 ft (5 m).
Repeatability ± 0.04 in. (1 mm).
Ambient Temperature Effect Less than 0.01% of measured distance per °C.
Update Interval 1 per second.
Measuring Range 16 in. (0.4 m) to 77 ft 1 in. (23.5 m). Also see page Level-8, 10 and Level-14.
(1) PFA is a fluoropolymer with properties similar to PTFE.
(2) 1 mm PTFE cover.
(3) Final rating may be lower depending on flange and O-ring selection, See “Tank Connection” on page 6.
Comentarios a estos manuales