Rosemount 3051
September 2014
www.rosemount.com
NACE certificate
Q15
(23)
Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials H
Q25
(23)
Certificate of Compliance to NACE MR0103 for wetted materials H
Typical model number: 3051L 2 A A0 D 21 A A F1
(1) Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
(2) Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to
HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
(3) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(4) Requires wireless options and engineered polymer housing. Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6),
ATEX Intrinsic Safety (option code I1), IECEx Intrinsic Safety (option code I7) and EAC Intrinsic Safety (option code IM).
(5) Only available with C6, E2, E5, I5, K5, KB and E8 approval. Not available with GE, GM, SBS, DA0, M4, D4, DZ, QT, HR5, HR7, CR, CS, CT.
(6) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(7) Not available with Wireless output (output code X).
(8) Only available with Wireless output (output code X).
(9) Not available with Product certifications options E8, K8, E5, K5, C6, K6, E7, K7, E2, K2, E3, KB, KD.
(10) Only valid with F
OUNDATION fieldbus output (output code F).
(11) Assemble-to” items are specified separately and require a completed model number.
(12) Dust approval not applicable to output code X. See
“IEC 62591 (WirelessHART Protocol)” on page 62 for wireless approvals.
(13) Only available with output codes A - 4-20mA HART, F - F
OUNDATION fieldbus, and W - PROFIBUS PA. Also only available with G1/2 housing thread types.
(14) Nonincendive certification not provided with Wireless output option code (X).
(15) Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, N7.
(16) Not available with F
OUNDATION fieldbus (Output Code F) or Wireless output (Output Code X) or Low Power (Output Code M).
(17) Contact an Emerson Process Management representative for availability.
(18) Only available with HART 4-20 mA output (output code A).
(19) Only available with 4-20 mA HART output (Output Code A) and Wireless output (Output Code X).
(20) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, and IE.
(21) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(22) Gasket provided when lower housing is ordered.
(23) NACE compliant wetted materials are identified by
Footnote 6.
Table 6. Rosemount 3051L Level Transmitter Ordering Information
H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Vista de pagina 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 83 84

Comentarios a estos manuales

Sin comentarios