IA ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus or PROFIBUS PA protocols only H
N1 ATEX Type n and Dust H
K8 ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1) H
E5 FM Explosion-proof, Dust Ignition-proof H
I5
(17)
FM Intrinsically Safe, Nonincendive H
IE FM FISCO Intrinsically Safe; for FOUNDATION fieldbus or PROFIBUS PA protocols only H
K5 FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5) H
C6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 H
I6
(9)
CSA Intrinsically Safe H
K6 CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1) H
E7 IECEx Flameproof, Dust Ignition-proof H
I7 IECEx Intrinsic Safety H
N7 IECEx Type n H
K7 IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7 and E7) H
E2 INMETRO Flameproof H
I2 INMETRO Intrinsic Safety H
IB INMETRO FISCO intrinsically safe; for FOUNDATION fieldbus or PROFIBUS PA protocols only H
K2 INMETRO Flameproof, Intrinsic Safety H
E3 China Flameproof H
I3 China Intrinsic Safety H
KB FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) H
KD CSA, FM, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8) H
Sensor fill fluid and O-ring options
L1
(18)
Inert Sensor Fill Fluid H
L2 Graphite-Filled (PTFE) O-ring H
LA
(18)
Inert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring H
Shipboard approvals
SBS
(18)
American Bureau of Shipping H
SLL
(18)(19)
Lloyds Register (LR)
Display and interface options
M4
(20)
LCD Display with Local Operator Interface H
M5 LCD Display H
Transient protection
T1
(18)(21)
Transient terminal block H
Manifold for remote mount option
F2 3-Valve Manifold, Stainless Steel H
F6 5-Valve Manifold, Stainless Steel H
PlantWeb control functionality
A01
(22)
FOUNDATION fieldbus Control Function Block Suite H
PlantWeb diagnostic functionality
DA0
(14)
Power Advisory HART Diagnostic H
D01
(22)
FOUNDATION fieldbus Diagnostic Suite H
Low power output
C2 0.8-3.2 Vdc Output with Digital Signal Based on HART Protocol (available with Output code M only)
Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information
H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.