Emerson CSI 9420 Especificaciones Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 78
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
Reference Manual
MHM-97408, Rev. 2
June 2008
3-11
CSI 9420
Connecting Sensors One or two accelerometers can be connected to the CSI 9420. Only one
accelerometer plus temperature sensor can be connected to the CSI 9420.
Table 3-2. Connection One
Accelerometer to the CSI 9420
Table 3-3. Connecting Two
Accelerometers to the CSI 9420
Connecting One Sensor / accelerometer
Connector labeled 1 -
Red wire
Connector labeled 2 -
White wire
Connector labeled 3 -
Blank
Connector labeled
4 - Black wire
Connecting Two Sensors / accelerometers
Connector labeled 1
-
Two red wires
(one from each
accelerometer)
Connector labeled 2 -
White wire from one
accelerometer
Connector labeled 3 -
White wire from other
accelerometer
Connector labeled 4
- Two black wires
(one from each
senor)
Vista de pagina 34