Emerson EZH and EZHSO Series Pressure Reducing Regulators Manual de instrucciones Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
OS2 NACE
6
Versions Installation Sealing Connection Mechanical connections
Electrical connections
Common NF NO Connection
C0 IP 68 Without 1/2 NPT cap
C1 Explosion IP 68
Explosion
3 m wire Black Blue Brown Wires
C2 proof IP 65
proof
Explosion proof connector box/PE explosion proof 3 4 5 Screwed wiring
C3 Intrinsical safe IP 68 Intrinsical safe tight-shut connector A B C Welded wiring
MAINTENANCE (BM)
Tools :
Spanner 11 (screw 7) and 13 (or 14) (screw 8)
Screwdriver
Control
Æ 1
st
and 2
nd
stage mechanism releasing
Æ Packing gland is tigh shut
Æ Yoke greasing
Disassembly
Æ Check that assembly is not under pressure
Æ Manual release of slam shut (drawing 7)
Æ Manually press on the releasing stem pin D1 or D2
(drawing 7, item 1) parallel to the BMS axe
Æ Unscrew the travel stop
(screwdriver)
Æ Unscrew the BM fastening screws
(flat spanner 11 (screw 7) and 13 (or 14) (screw 8)
Æ Disassemble the mechanism box (BM) from the connector
by unlocking the yoke
Assembly
Æ Proceed in reverse order to disassembly
OPTIONS (BM)
Remote alert (on BM 1 or BM 2)
Detects 2
nd
stage releasing (power)
Remote control
Atmospheric solenoid valve (releasing by min. pressure) for
max. releasing pressure of 30 bar. Safety manometric box
(BMS) activated with a pneumatic or electro-pneumatic impulse.
Manual control on BM 2 with 1 BMS 1 only
Push button (connected at the same place as a BMS 2).
Versions
BK
BU
BN
A
B
C
NF --> BK(A)/BU(B)
NO --> BK(A)/BN(C)
WIRING
BK
BU
BN
123456
NF --> BK(3)/BU(4)
NO --> BK(3)/BN(5)
WIRING
BK
BU
BN
NF --> BK/BU
NO --> BK/BN
WIRING
È
È
3 m
NF : Normally closed
NO : Normally opened
N13
Version C1 connection
Explosion proof connection with cable
and tight-shut packing gland
Version C2 connection
Explosion proof connection
with explosion proof
connector box
Version C3 connection
Explosion proof connection
with sealed connector
for intrinsic safe
N14
N15
8b - Differents versions of BM OS2 connections
AC DC
Max. intensity 7.0 A 0.8 A
Max. tension 400 V 250 V
Protection EEx-d IIC T6
Tightness IP 66
Temperature - 29°C + 71°C
Fastening 2 M3 screws
Cable
3 wires (black, brown, blue) H05VVF
(3 x 0.75 mm²) D 6.5 mm
Contact
Europe, Middle East, and Africa Document Only
Vista de pagina 5
1 2 3 4 5 6 7 8 9 10 11 12

Comentarios a estos manuales

Sin comentarios