Type OS2
5
TRAVEL STOP
Table 7. Packing Gland Material
Body Bronze - - - -
Control rod Stainless steel Chromium plating
Truarc ring Nitrile (NBR) - - - -
CAUTION
Never use an extension pipe with the reset key
when resetting the 2nd stage (max. normal
torque 16 N•m, never go over 32 N•m).
!
WARNING
AUTHORIZED PERSONNEL ONLY
Risk of injury
After rearming, remove the reset key from
the stem. Do not put fingers in or near the
reset mechanism area.
VALVE
CLOSED POSITION
N10
Figure 15. Release Activation Stages
TRAVEL STOP
TRAVEL STOP
RESET DETECTION STAGE RESET POWER STAGE
VALVE VALVE
N11
N12
MAINTENANCE (BM)
• Tools:
- Spanner 11 (screw 7) and 13 (or 14) (screw 8)
- Screwdriver
• Control
- 1st and 2nd stage mechanism releasing
- Packing gland is tight shut
- Yoke greasing
• Disassembly
- Check that assembly is not under pressure
- Manual release of slam shut (Figure 14)
- Manually press on the releasing stem pin D1 or D2
(Figure 14, key 1) parallel to the BMS axe
- Unscrew the travel stop (screwdriver)
- Unscrew the BM fastening screws (flat spanner 11
(screw 7) and 13 (or 14) (screw 8)
- Disassemble the mechanism box (BM) from the
connector by unlocking the yoke
• Assembly
- Proceed in reverse order to disassembly
Note
The position of the travel stop (Figure 10,
key 7) depends on the type of assembly and
its size. Position A, B or C depending on
max. travel of slam shut valve: A = 15 mm
travel, B = 35 mm travel, C = 50 mm travel.
• Mechanism box (BM) intervention
To access the box the cover must be removed. When
unscrewing the nut a circlips is used to remove the O-ring.
The cover is held on by one screw which can be unscrewed
manually or using a socket screw key (recommended torque
foroptimalshutoff:6N•m).
• Resetting
To reset the slam shut (after the fault has been settled), the
1st mechanism stage must be reset by manually turning the
1st stage trigger. If the slam shut has an internal bypass the
cam must be slightly turned using a resetting key to bypass.
If the slam shut has an external bypass, a bypass valve will
be used. In both cases:
- Wait for the pressure to be equalized before resetting
the 2nd mechanism stage.
- When resetting the 2nd mechanism stage (opening of
the valve) a reset key is used (delete).
OPTIONS (BM)
• Remote alert (on BM1 or BM2)
Detects 2nd stage releasing (power)
• Remote control
Atmospheric solenoid valve (releasing by min. pressure)
for max. releasing pressure of 30 bar. Safety manometric
box (BMS) activated with a pneumatic or electro-
pneumatic impulse.
• Manual control on BM2 with 1 Type BMS 1 only
Push button (connected at the same place as a
Type BMS 2).
Comentarios a estos manuales