High Heat Density Solutions For Rack,
Spot And Zone Cooling
Mission-critical heat removal systems can
now be configured to target cooling directly
at hot spots. Unique equipment designs
also enable users to handle high heat loads
without consuming additional floorspace.
Data Center Cooling Solution
Starts With The Best
A Liebert DS Mission-Critical Cooling
System provides basic cooling, humidity
control and air filtration.
The Liebert XD
System Provides
Supplemental Sensible Cooling
For High Heat Density Racks
Or Zones.
Product Features Include:
Energy efficient.
Can cool more than 30kW per rack.
Pumped refrigerant solutions are ideal
for use around electronic equipment.
Minimal floorspace requirements.
Flexibility to accommodate various
equipment layouts.
Scalable – add or move cooling
modules as your needs change
without the need for an HVAC
technician.
12
Supplemental Sensible Cooling
Pumped refrigerant
Pumped refrigerant
technology is ideal
for use around
electronic equipment.
It operates at low
pressure in the piping
circuit and would
become a gas
at room conditions.
Use of pumped
refrigerant also
makes the system
very energy efficient
and it saves space
with smaller piping
requirements and
the ability to utilize
more compact heat
exchangers.
Liebert XD
Series Rack, Zone And Spot Cooling:
Flexible Configurations For Many Applications
Space-Saving
Solution That
Cools From
The Top
The
Liebert XDV
Cooling Module
mounts vertically
above or on the IT rack
enclosure, drawing
hot air from inside the
cabinet or from the
hot aisle. It then cools
the air and discharges
it down to the cold
aisle. This space-saving
solution requires zero
floor space. Available
with Smart Module
integrated control
board, for increased
module control and
monitoring.
A Chiller Designed
For Direct System
Configurations
The Liebert XDC
Chiller is a specially
designed indoor
unit that connects
directly to the
Liebert XD Cooling
Modules and
provides chilled
pumped refrigerant
circulation and
control. It ensures
that the refrigerant
is constantly above
the actual dew
point in the room,
eliminating concern
about condensation.
Available with several
heat rejection options.
The Overhead
Cooling Solution
The ceiling-mounted
Liebert XDO Overhead
Cooling Module
mounts directly above
the cold aisle. It draws
in hot air from the
hot aisle and then
discharges cool air
into the cold aisle
where the equipment
air inlets are located.
This energy-efficient
unit takes up no floor
space. Available with
Smart Module
integrated control
board, for increased
module control and
monitoring.
Pumped Refrigerant Approach
Pumping Unit
Designed
For Indirect
Configuration
Applications
When a building chilled
water system is
available, the Liebert
XDP with iCOM
Pumping Unit serves
as an isolating interface
between the building
chilled water system
and the pumped
refrigerant circuit. It
circulates refrigerant to
the XD Cooling Modules
at a temperature always
above the actual dew
point to prevent
condensation. Liebert
XDP features Liebert
iCOM controls,
enhancing system
reliability and flexibility.
Total Data Center Cost (less land)
($000)
Cooling System
Data Center Cost (New Construction)
Liebert XD - Supplemental Cooling
Requires less Chiller Capacity
Liebert XD - Supplemental Cooling
with Lower Operating Costs
$30,000
$25,000
$20,000
$15,000
$10,000
$5,000
$0
Building Cost
Less Cooling
50 W/sq.ft
(500 W/m
)
150 W/sq.ft
(1500 W/m )
Fixed Load of 4,000 kW
400 W/sq.ft
(4000 W/m )
Building Size
2 2 2
Power Usage
0.00
0.10
0.20
0.30
0.40
0.50
0.60
CW CRAC
at 100%
Capacity
CW CRAC
at 50%
Capacity
Liebert XD
at 100%
Capacity
Liebert XD
at 50%
Capacity
kW power to cool 1 kW of sensible heat
Fan
Pump (XD)
Pump (CW)
Chiller
Chiller Capacity
0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
CW CRAC Liebert XD
kW Chiller Capacity per kW
Of Sensible Heat Load
Latent Load
Fan Load
Sensible Load
15% Lower
27% Lower
32% Lower
80,000 sq.ft.
8,000 m
2
27,000 sq.ft.
2,700 m
2
10,000 sq.ft.
1,000 m
2
The smaller chiller
plant and lower
fan load result in
significant energy
savings. A 27%
energy savings is
very conservative.