6
All Modules
ENVIRONMENTAL
(Minimum of 400 LFM of forced air cooling
is recommended for operation in the higher
temperature ranges.)
Operating Non-operating
Temperature: 0° C to +55° C
(inlet air temp.
with forced air
cooling*)
–40° C to +85° C
Humidity (NC): 5% to 90% 5% to 90%
Vibration: 2 Gs RMS,
20–2000 Hz
random
6 Gs RMS,
20–2000 Hz
random
ELECTROMAGNETIC COMPATIBILITY (EMC)
Intended for use in systems meeting the following
regulations:
U.S.: FCC Part 15, Subpart B, Class A c
(non-residential)
Canada: ICES-003, Class A (non-residential) c
This product was tested in a representative system
to the following standards:
CE Mark per European EMC Directive 89/336/EEC c
with Amendments; Emissions: EN55022 Class B;
Immunity: EN55024
SAFETY
All printed wiring boards (PWBs) are manufactured
with a ammability rating of 94V-0 by UL recognized
manufacturers.
DEMONSTRATED MTBF
(based on a sample of eight boards in accelerated
stress environment)
Mean: 190,509 hours
95% Condence: 107,681 hours