15
attaching cap, check that travel indicator
is aligned on the cap and on the upper
actuator casing.
21. Mount O-ring (key 75) on the space between
the cap (key 70) and the upper actuator casing
(key 11).
22. Screw the eyebolts (key 35) on the cap (key 70).
NPS 4 / DN 100 Disk Maintenance
(EZHSO Series Only) (Refer to Figure 9)
1. Remove cap screws (key 77).
2. Carefully lift the cap (key 70) off of the upper
actuator casing (key 11).
3. Remove O-ring (key 75). Inspect the O-ring for
damage or wear and replace if necessary.
4. Remove O-ring (key 69). Inspect the O-ring for
damage or wear and replace if necessary. Lubricate
O-ring before placing inside the cap (key 70).
5. Remove special screws (key 68) from sleeve.
6. Carefully remove the trim system from the sleeve
guide (key 61) utilizing the eyebolt (key 35) or
stem nut.
7. Remove socket head cap screws (key 154).
8. Lift off the disk holder assembly (key 30).
9. Remove the O-ring (key 29). Inspect the O-ring
for damage or wear and replace if necessary.
Lightly lubricate O-ring before placing in the sleeve
adaptor (key 27).
10. Place disk holder assembly (key 30) into sleeve
adaptor (key 27) and align screw holes.
11. Place on socket head cap screw (key 154).
Screw together the disk holder assembly (key 30)
into the sleeve adaptor (key 27). See Torque
Specications (Table 4) for proper torque values.
12. Lubricate the sleeve (key 14).
13. Carefully insert the trim system into the sleeve
guide (key 61). Align sleeve utilizing the socket
hex cap screw (key 74) as a guide.
14. Screw special screws (key 68) to afx the sleeve
system. See Torque Specications (Table 4) for
proper torque values.
15. Place O-ring (key 69) on the cap (key 70).
16. Carefully place the cap (key 70) on the upper
actuator casing (key 11).
17. Lubricate the cap screws (key 77) before
screwing in to hold the cap (key 70) and the upper
actuator casing (key 11) together. See Torque
Specications (Table 4) for proper torque values.
Note
Rotate the cap such that the outer holes
for sensing lines are in line with upper
casing holes for sensing lines: to validate
the alignment and before attaching cap,
check that travel indicator is aligned on
the cap and on the upper casing.
18. Mount O-ring (key 75) on the cap.
NPS 1 through 3 / DN 25 through 80
Intermediate Flange O-ring Maintenance for
EZH and EZHSO Series
1. Remove nuts (key 26).
2. Carefully lift the upper actuator casing and lower
actuator casing assemblies (keys 11 and 5) off
the body (key 1).
3. Remove cap screws (key 6).
4. Lift off intermediate ange (key 25).
5. Remove O-ring (key 7). Inspect the O-ring for
damage or wear and replace if necessary. Lightly
lubricate O-ring before placing in the body (key 1).
6. Place the intermediate ange (key 25) on the body,
make sure to position the stud bolt (key 24) holes
on the outsides of the body (key 1). Secure with cap
screws (key 6). See Torque Specications (Table 4)
for proper torque values.
7. Carefully lift the upper actuator casing and lower
actuator casing assemblies (keys 11 and 5) and
position it in the body (key 1).
8. Screw in stud bolts and nuts (keys 24 and 26).
See Torque Specications (Table 4) for proper
torque values.
NPS 1 through 3 / DN 25 through 80
Actuator Assembly Maintenance
(Refer to Figures 8 and 9)
For EZH Series:
1. Make a mark on the upper actuator casing
(key 11), lower actuator casing (key 5),
intermediate ange (key 25) and body (key 1) to
indicate proper alignment.
2. Remove travel indicator assembly (keys 138,
139, 140, 141, 142A or 142B, 143, 144, 145,
160 and 192), if present, by loosening the
Vista de pagina 14