Emerson 92C Manual de instrucciones Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
Type 92C
12
8. When maintenance is completed, refer to the
Startup section to put the regulator back in
operation and to adjust the pressure setting.
Type 6392 Pilot
Perform this procedure if inspecting, cleaning, or
replacing any pilot parts. Key numbers refer to Figure 9
unless otherwise specied.
All pilot maintenance may be performed with the pilot
body (key 1) attached to the pipe nipple and connector
(keys 23 and 24, Figure 10) unless the pilot body must
be removed or the pilot is to be replaced as a unit.
1. Loosen the jam nut (key 15), and turn the
adjusting screw (key 16) counterclockwise until all
compression is removed from the control spring
(key 13). Remove the loading tubing from the
pilot outlet connection. Remove the cap screws
(key 17), spring case (key 2), control spring
(key 13), and upper spring seat (key 14) from
the body.
2. Remove the lower spring seat (key 9), the diaphragm
(key 7), and the diaphragm gasket (key 8) from
the body. Lift out the stem assembly (key 6)
consisting of the stem and the pusher plate.
Clean the 1/16-inch / 1.6 mm diameter pilot bleed
hole. Clean and replace parts as necessary, and
assemble the stem assembly, the gasket, the
diaphragm, and the spring seat in the order shown
in Figure 9.
3. Install the control spring (key 13), the lubricated
upper spring seat (key 14), and the spring case
(key 2). Insert and tighten the cap screws (key 17).
Lubricate the adjusting screw (key 16) with
Never-Seez* or equivalent lubricant, and thread it
into the spring case.
4. Unscrew the valve plug guide (key 5). Remove
the strainer screen (key 12), the valve plug
(key 4), the valve plug cap (key 26), and the
valve plug spring (key 11). Unscrew the orice
(key 3). Clean and replace parts as necessary.
Apply Never-Seez* or equivalent lubricant to the
orice threads, and screw the orice into place.
5. Place the valve plug spring (key 11) into the valve
plug guide (key 5). Insert the valve plug cap
(key 26) into the valve plug (key 4), and then slide
both parts over the spring and into the valve plug
guide. Place the strainer screen (key 12) onto the
valve plug guide. Apply Lok-Cease 20/20
sealant
or equivalent (key 21) to the valve plug guide
threads, and screw the valve plug guide with the
attached parts into the pilot body (key 1).
6. When maintenance is completed, refer to the
Startup section to put the regulator back into
operation, and adjust the pressure setting.
Types 6492HM and 6492HTM
Safety Override Pilots
These procedures are to be performed if inspecting,
cleaning, or replacing any pilot parts, or of cycling,
erratic control, or too high or too low an outlet (control)
pressure is noted. Perform only those procedures
in this section required to correct the problem. Key
numbers refer to Figure 11.
Note
Before performing any maintenance,
loosen the hex nut (key 16), if used,
and turn the adjusting screw (key 15) or
handwheel (key 31) counterclockwise
until all compression is removed from
the control spring (key 12). Remove the
pilot spring from the pipe nipple and
connectors (keys 82 and 83, Figure 12).
1. Unscrew the plug guide (key 2). Remove the
screen (key 77), inner valve (key 4), plug spring
(key 3), and stem (key 7). Unscrew the orice
(key 5). Examine the orice and plug seating
surfaces for damage.
2. Clean and replace parts as necessary. Apply
sealant to the orice threads. Thread the orice
into place and tighten using 19 to 25 foot-pounds /
26 to 34 N•m of torque.
3. Handle parts carefully, and place the plug spring
(key 3) in the plug guide (key 2). Slide the inner
valve (key 4) over the spring and into the plug
guide. Place the screen (key 77) onto the plug
guide. Place the stem (key 7) in the center hole
of the plug guide. Apply sealant to the plug guide
threads, and screw the guide plus attached parts
into the body (key 1).
4. Remove the pipe plug (key 74). Then remove the
pipe plug (key 94). Clean and replace the pipe
plugs as necessary.
5. Apply sealant to the threads of the pipe plug
(key 94) and install.
* Trademark of Never-Seez Corp.
† Trademark of Certied Laboratories
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16

Comentarios a estos manuales

Sin comentarios