Type LR128
5
Table 1. Type LR128 Main Valve Body Sizes, End Connection Styles, Structural Design Ratings and Maximum Operating Inlet Pressures
(1)
MAIN VALVE
BODY SIZE
MAIN VALVE
BODY
MATERIAL
END CONNECTION STYLE
(2)
STRUCTURAL DESIGN
RATING
(3)
MAXIMUM OPERATING
RELIEF (INLET)
PRESSURE INCLUDING
BUILD-UP
(3)
MAXIMUM OPERATING
OUTLET PRESSURE
In. DN psig bar psig bar psig bar
1, 2,
3 and
4
25, 50,
80 and
100
WCC Steel
NPT or SWE (1 and 2 in. only) 1500 103 450 31.0 450 31.0
CL150 RF 290 20.0 290 20.0 290 20.0
CL300 RF 750 51.7
450 31.0 450 31.0CL600 RF 1500 103
PN 16/25/40 RF 580 40.0
CF8M
Stainless steel
NPT (1 and 2 in. only) 1440 99.2 450 31.0 450 31.0
CL150 RF 275 19.0 275 19.0 275 19.0
CL300 RF 720 49.6
450 31.0 450 31.0CL600 RF 1440 99.2
PN 16/25/40 RF 580 40.0
1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
2. Ratings and end connections for other than ASME standard can usually be provided. Contact your local Sales Ofce for assistance.
3. Maximum cold working pressure (CWP) per ASME B16.34 or product bulletin limit, whichever is lowest. Temperature may decrease these maximum pressures.
Table 2. Type MR98H Pilot Maximum Cold Working Pressure
(1)(2)
BODY SIZE
BODY AND SPRING
CASE MATERIAL
MAXIMUM INLET PRESSURE MAXIMUM OUTLET PRESSURE
1/2 NPT
Steel
Stainless steel
450 psig / 31.0 bar 450 psig / 31.0 bar
1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
2. Temperature and/or the body end connection may decrease these maximum pressures.
Table 3. Relief Set Pressure or Backpressure Control Ranges
!
WARNING
Liquid pressure control systems should
be designed using engineering practices
to eliminate quick control starting or
stopping of the ow stream, which can
produce water hammer.
The robust design of the Type LR128 allows this relief
valve or backpressure regulator to be installed indoors
or outdoors. Type LR128 is designed to withstand the
elements. The powder paint coating protects against
minor impacts, abrasions and corrosion. When installed
outdoors, the Type LR128 does not require protective
housing. However, the Type MR98H pilot should be
oriented so that the pilot spring case vent is pointed
down. Otherwise, make sure the vent is protected
so that rain, moisture, insects or any debris will not
accumulate inside or block the vent assembly.
When installed indoors, no remote venting is required
except on the pilot spring case. Refer to Step 8 of the
following procedure for the correct venting practices.
1. Only personnel qualied through training and
experience should install, operate and maintain
a relief valve or backpressure regulator. Before
installation, make sure that there is no damage
to or debris in the main valve body or pilot. Also,
make sure that all tubing and piping are clean
and unobstructed.
PILOT
SET PRESSURE RANGE SPRING WIRE DIAMETER SPRING FREE LENGTH
SPRING MATERIAL
SPRING PART NUMBER
AND COLOR
psig bar In. mm In. mm
Type
MR98H
25 to 75
70 to 140
130 to 200
150 to 375
(1)
1.7 to 5.2
4.8 to 9.7
9.0 to 13.8
10.3 to 25.9
(1)
0.234
0.283
0.331
0.394
5.94
7.19
8.41
10.0
2.595
2.44
2.250
5.063
65.9
62.0
57.2
129
Powder-coated steel
Powder-coated steel
Powder-coated steel
Powder-coated steel
ERAA01910A0, Green
ERAA01911A0, Red
ERAA02889A0, Blue
1N943427142, Unpainted
1. 150 to 375 psig / 10.3 to 25.9 bar spring range is for the Type MR98HH pilot construction.
Comentarios a estos manuales