Type EZR
6
PRINCIPLE OF OPERATION
B18A
Figure 7. Type EZR E Body with PRX Pilot
Regulator
The EZR is a pilot-driven, diaphragm/plug regulator.
Tight shutoff is achieved by the diaphragm/plug pushing
against the slotted cage, the force of the closing spring and
the inlet pressure.
Opening•
As the ow increases, the outlet pressure Pd decreases
on the outlet side of the regulator and on the pilot diaphragm.
Due to the force of the spring, the pilot opens.
The pilot ow increases, the pressure loss through the
pilot restrictor increases.
The modulated pressure Pm decreases.
The force of the closing spring and that of the
Pm becomes inferior to that provoked by the Pu,
the regulator OPENS.
Closing•
As the ow decreases, the Pd increases outlet side
of the regulator.
The force of the pilot diaphragm is overcome by the force
of the spring, the pilot closes.
The pressure loss through the pilot restrictor decreases.
The force of the closing spring and that of the Pm
becomes superior to that provoked by the Pu, the
regulator CLOSES.