15
Standard Pilots
PILOT SETTING RANGES
Table 8. Distribution Regulators Range
A108
DISTRIBUTION
REGULATORS
Pd (bar) PRE-EXPANSION RELAY PILOTAGE
MANOMETER
RANGE
(bar)
RELIEF VALVE
(1)
Nominal
Pd
Range Type Size
PSD
(bar)
Wire
(mm)
Type Size
PSD
(bar)
Wire
(mm)
Maxi
Setting
(bar)
Setting
(bar)
EZR
0.02 0.01 to 0.05
Diaphragm
114 10 5.5
Diaphragm
162 5
2
0 - 6
10.3
5
0.10 0.05 to 0.18 3
0.30 0.18 to 0.77
114 10
4
6
1.00 0.77 to 1.20
071 20
4.5 4.5
0 - 162.00 1.00 to 2.40
5.5
5.5 7
4.00 2.40. to 4.80 6.5 10
8.00 4.80 to 10.50
6.5 071 20
5.5
0 - 40 24.3
16
16.00 10.50 to 18.00 Bellows 236 35 6.5 23
K1000
K3000
0.02 0.01 to 0.05
Diaphragm
114 10
4.5 162 5
2
0 - 6
10.3
5
0.10 0.05 to 0.18 3
0.30 0.18 to 0.77
5.5
114 10
4
1.00 0.77 to 1.20 4.5
2.00 1.20 to 2.40
071 20
4.5 5.5
0 - 164.00 2.40. to 4.80 5.5 6.5 7
8.00 4.80 to 10.50
6.5 071 20
5.5
24.3
13
16.00 10.50 to 16.00 Bellows 236 35 6.5 0 - 40 18
(1) Note: If Pu <= 10 bar and Pd <= 8 bar. the relief valve is removed and replaced by a plug.
Europe, Middle East, and Africa Only
Comentarios a estos manuales