Bulletin 71.1:CSB400
11
Table 8. Regulator and Slam-shut OPSO and UPSO Pressure Ranges
Example: If a non-standard setpoint is needed, see the following example for instruction in using Table 8.
Non-standard setpoint = 140 mbar / 2 psig, then the factory set of the token relief will be 1.3*140 = 182 mbar /
2.6 psig. The factory OPSO and UPSO set values will be 165% of set and 50% of set, respectively, resulting is
values of 231 mbar / 3.4 psig and 70 mbar / 1 psig, also respective to OPSO and UPSO.
TYPE
REGULATOR SLAM-SHUT MODULE
Set Pressure
Range
Standard
Setpoints
Token Relief
Set
(1)(2)
Available
Token Relief
Range Shown
as a % of
Regulator
Setpoint
Overpressure Shutoff (OPSO) Underpressure Shutoff (UPSO)
Minimum
Required
Difference
between
Token Relief
and OPSO Set
Standard
OPSO Set
Values
(1)
P
dso
OPSO Set
Range as a %
of Regulator
Setpoint
Standard
UPSO Set
Values
(1)
P
dsu
UPSO Set
Range as a %
of Regulator
Setpoint
mbar psig mbar psig mbar psig Min
(2)
Max mbar psig mbar psig Min Max mbar psig Min Max
CSB404,
CSB404F and
CSB414
17 to
24
0.25 to
0.35
20 0.29 34 0.49
170 215 8 0.12
43 0.62
215% 270%
10 0.15
50 56
21 0.30 36 0.52 45 0.65 11 0.16
24 to
35
0.35 to
0.51
27 0.39 41 0.59
150 160 10 0.12
51 0.74
190% 200%
14 0.20
50 60
30 0.44 45 0.65 57 0.83 15 0.22
35 0.50 53 0.76 67 0.96 18 0.26
35 to
60
0.51 to
0.87
50 0.70 70 1.0
140 158 16 0.23
90 1.3
180% 200%
25 0.36
50 70
60 0.87 84 1.2 108 1.57 30 0.44
54 to
100
0.78 to
1.5
75 1.10 98 1.4
130 140 20 0.29
128 1.85
170% 190%
38 0.54
50 70
100 1.5 130 1.9 170 2.47 50 0.73
CSB424,
CSB424F and
CSB434
100 to
160
1.5 to
2.3
150 2.2 195 2.8
130 140 40 0.58
248 3.59
165% 175%
75 1.1
50 70
160 2.3 208 3.0 264 3.83 80 1.2
138 to
300
2.0 to
4.4
300 4.4 375 5.4 125 140 50 0.73 450 6.53 150% 165% 150 2.2
276 to
517
4.0 to
7.5
500 7.3 625 9.1 125 140 60 0.87 700 10.2 140% 180% 250 3.6
CSB454
(3)
500 to
1000
7.3 to
14.5
1000 14.5 - - - - - - - - - - - - - - - - - - - - - - - - 1320 19.2 112% 140% 500 7.3
50 70
1000 to
3000
14.5 to
43.5
1200 17.4 - - - - - - - - - - - - - - - - - - - - - - - - 1600 23.2 112% 133% 600 8.7
1500 21.6 - - - - - - - - - - - - - - - - - - - - - - - - 1900 27.6 112% 127% 750 10.9
2000 29.0 - - - - - - - - - - - - - - - - - - - - - - - - 2400 34.8 112% 120% 1000 14.5
3000 43.5 - - - - - - - - - - - - - - - - - - - - - - - - 3400 49.3 112% 113% 1500 21.8
1. Standardfactorysetshown.FactorysetisattheMinimumvalueoftherangeindicated.RangeindicatedisapercentageofSetpoint.PercentageindicatedisbasedontheSetPressure
Rangeinwhichthatsetpointresides.Ifnon-standardsetsarerequired,adherencemustbemadetoconstraintsshowninTable7,includingTokenReliefSetRange,OPSOandUPSOset
rangeandMinimumRequireddifferencebetweenTokenReliefandOPSOSet.
2. MinimumTokenReliefvaluesapplyto-20to60°C/-4to140°Fservicetemperatures.Forservicebelow-20°C/-4°F,add8mbar/0.12psigtotheminimumTokenReliefvaluelisted.
3. TokenReliefisnotavailablefortheTypeCSB454.