Types 1301F and 1301G
D100341X012
Instruction Manual
Form 1111
December 2013
www.fisherregulators.com
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
re and/or chemical contamination
causing property damage and personal
injury or death.
Fisher
®
regulators must be installed,
operated, and maintained in accordance
with federal, state and local codes, rules
and regulations, and Fisher instructions.
If the regulator vents gas or a leak
develops in the system, service to the unit
may be required. Failure to correct trouble
could result in a hazardous condition.
Installation, operation, and maintenance
procedures performed by unquali ed
personnel may result in improper
adjustment and unsafe operation. Either
condition may result in equipment
damage or personal injury. Use quali ed
personnel when installing, operating,
and maintaining the 1301 Series high-
pressure regulator.
Introduction
Scope of the Manual
This Instruction Manual provides instructions for the
installation, adjustment, maintenance, and parts ordering
of the Types 1301F and 1301G high-pressure regulators.
Product Description
Types 1301F and 1301G regulators are direct-operated,
high-pressure regulators, which can be used where
high-pressure gas must be reduced for use as pilot
1301 Series High-Pressure Regulators
supply pressure in pilot-operated regulators or as
loading pressure in pressure-loaded regulators.
Types 1301F and 1301G regulators can also be used
in many other applications due to their rugged design
as high-pressure reducing regulators for various  uids
such as air, gas, water, and other liquids.
The Type 1301F can handle outlet pressures from
10 to 225 psig / 0.69 to 15.5 bar in three ranges and
the Type 1301G can handle outlet pressures from
200 to 500 psig / 13.8 to 34.5 bar in one range.
Figure 1. Type 1301F High-Pressure Regulator
P1025
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - Types 1301F and 1301G

Types 1301F and 1301GD100341X012Instruction ManualForm 1111December 2013www.fisherregulators.com!WARNINGFailure to follow these instructions or to pro

Pagina 2

Types 1301F and 1301G2Available Congurations Type 1301F: Direct-operated, high-pressure reducing regulator for inlet pressures to 6000 psig / 414 bar

Pagina 3

Types 1301F and 1301G3Principle of OperationThe 1301 Series regulators are direct-operated. Downstream pressure is registered internally through the b

Pagina 4

Types 1301F and 1301G4Installation!WARNINGOverpressuring a regulator or associated equipment may cause leakage, part damage, or personal injury due t

Pagina 5

Types 1301F and 1301G5MaintenanceRegulator parts are subject to normal wear and must be inspected and replaced as necessary. The frequency of inspect

Pagina 6

Types 1301F and 1301G6CD3923_FFigure 3. Type 1301F High-Pressure Regulator AssemblyFigure 4. Type 1301G High-Pressure Regulator Assembly152111916113

Pagina 7

Types 1301F and 1301G7Parts OrderingWhen corresponding with your local Sales Ofce about this regulator, include the type number and all other pertine

Pagina 8

Types 1301F and 1301G©Emerson Process Management Regulator Technologies, Inc., 1975, 2013; All Rights ReservedThe Emerson logo is a trademark and serv