Menu Options Description • Homeowner Manual
16
 0 – (Default) Displays the measured room temperature.
-1° through -5° – Adjusts the displayed temperature the
specified number of degrees lower than the measured room
temperature.
6. Thermostat Settings – Energy Mgmt Recovery
Options for this menu item include:
 OFF – (Default) The system starts heating or cooling at the
start time for the program period.
 ON – The system starts heating or cooling before the start
time for the program period so that the room temperature
reaches the program setpoint at the period start time.
Example: You select EMR ON and have your heat (conventional
heating system) programmed to 65° at night and 70° at 7:00
AM (a difference of 5°). Allowing 7 minutes per degree, the
thermostat will start calling for heat prior to the 7:00 AM period
start time in an attempt to reach the 70° setpoint by 7:00 AM.
With EMR OFF, the thermostat will wait until the 7:00 AM period
start time to begin heating the home.
7. Thermostat Settings - °F/°C
You can display temperature in either:
 °F – (Default) Fahrenheit
 °C – Celsius (Centigrade)