A31A Valve
Instruction Manual
Form 5291
March 2008
2
Table 1. Specifications
Valve Size and End Connection Styles
NPS J 14, J 16, J 18, J 20, and J 24 valves,
and in J wafer-style (flangeless) or
J single-flange (lugged) with raised-face flanges,
CL150 or 300
Maximum Pressure Drop
(1)
Consistent with CL150 and 300
pressure/temperature ratings per ASME B16.34
unless further restricted by values given in
figure 2
Shutoff Classification Per ANSI/FCI 70-2
and IEC 60534-4 or MSS SP-61
Standard Soft Seal: Bidirectional shutoff Class VI
(bubble-tight)
NOVEX Seal: Unidirectional shutoff MSS SP-61
(reverse flow direction only) Class VI optional
Phoenix III Seal: Bidirectional shutoff Class VI
(bubble-tight)
Phoenix III Seal for Fire-Tested Applications:
Unidirectional shutoff Class VI (reverse flow
direction only) (bubble-tight).
Fire Tested per API 607 Rev. 4
Available Seal Configurations
Standard Constructions
See figure 3 and table 2
Standard Construction Materials
See table 2
Material Temperature Capabilities
(1)
See table 2
Flow Characteristic
Modified equal percentage
Flow Coefficients
See Catalog 12 and bulletin 21.1:A31A
Flow Coefficient Ratio
(2)
100 to 1
Noise Levels
See Catalog 12 for sound/pressure level
prediction
Valve In-Line Position
Shaft horizontal. See figure 4
Valve/Actuator Action
With diaphragm or piston rotary actuator,
field-reversible between:
J push-down-to-close (extending actuator rod
closes valve) and
J push-down-to-open (extending actuator rod
opens valve)
Valve Body Classification
Face-to-face dimensions are in compliance with
MSS SP68 and API 609 standards; Valve bodies
are designed for installation between ASME
B16.5 CL150 and 300 raised-face flanges
Disc Rotation
Clockwise to close (when viewing from the drive
shaft end) through 90 degrees rotation
Shaft Diameter and Approximate Weight
See tables 3 and 4
ENVIRO-SEALr Packing
This optional packing system provides improved
sealing, guiding, and transmission of loading force
to control liquid and gas emissions. Contact your
Emerson Process Management sales office for
availability of ENVIRO-SEAL packing
1. The pressure/temperature limits in this manual, and any applicable code or standard limitation should not be exceeded.
2. Ratio of maximum flow coefficient to minimum usable flow coefficient may also be called rangeability.