Monitoring
For Business-Critical Continuity™
Liebert
®
SiteLink-E
Installation Manual - Liebert SiteLink-2E, Liebert SiteLink-4E and Liebert SiteLink-12E
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - SiteLink-E

MonitoringFor Business-Critical Continuity™Liebert ®SiteLink-E™ Installation Manual - Liebert SiteLink-2E, Liebert SiteLink-4E and Liebert SiteLink-12

Pagina 2 -

Connect Input Power Wiring63.2 Connect Input Power—AC or DCLiebert SiteLink-E modules may be powered with either alternating current or direct current

Pagina 3 - TABLE OF CONTENTS

Communication and Control Wiring74.0 COMMUNICATION AND CONTROL WIRINGNOTICECommunication wiring must be performed in accordance with industry standard

Pagina 4

Communication and Control Wiring84.1.1 Wiring IGM Ports 1. Connect the IGM wiring to the SiteLink-E IGM ports, using the labels above the ports as a g

Pagina 5 - 1.0 PRODUCT OVERVIEW

Communication and Control Wiring94.2 RS-485 and ARC156 Wiring ConsiderationsAn RS-485 network is intended to be configured as a linear bus with daisy-

Pagina 6 - 2.2 Enclosure Diagrams

Communication and Control Wiring10Figure 10 Liebert SiteLink-E modules in ARCnet network4.4 Wiring Port S1Port S1 on the Liebert SiteLink-E accommodat

Pagina 7

Communication and Control Wiring114.4.2 Wiring Port S1 for RS-485—Two-WireFor connecting the Liebert SiteLink-E Port S1 to a BMS that uses two-wire RS

Pagina 8 - 0.16"

Communication and Control Wiring124.4.3 Wiring Port S1 for RS-232When connecting the Liebert SiteLink-E Port S1 to a third-party device that uses RS-2

Pagina 9 - 3.1 Power Wiring

Specifications135.0 SPECIFICATIONSTable 1 SpecificationsPHYSICALModule Dimensions, W x H x D, in. (mm) 11-1/4 x 7-1/2 x 1-1/4 (286 x 191 x 32)Enclosur

Pagina 10 - 24ac/26dc

Specifications14The Liebert SiteLink-E communicates using BACnet and/or third-party protocols, and can connect to a variety of port types at multiple

Pagina 11 - 4.1 IGM Communication

15APPENDIX A-COMMUNICATION PROTOCOL AND WIRING CONSIDERATIONSA.1 Differences Between RS-485 and RS-422Third-party manufacturers sometimes specify a de

Pagina 13 - Over ARCNET156 KBaud

16A.3 BiasData collisions occur when two devices enable their transmitters at the same time; these are likely to occur on RS-485/RS-422 networks. A ma

Pagina 17 - 5.0 SPECIFICATIONS

Ensuring The High Availability0f Mission-Critical Data And Applications.Emerson Network Power, the global leader in enabling business-criticalcontinui

Pagina 18

iTABLE OF CONTENTS1.0 PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.0 I

Pagina 19 - A.2 Termination

iiFIGURESFigure 1 Liebert SiteLink-E layout—power and communication connections, ports and switches . . . . . . . 1Figure 2 Module dimensions, witho

Pagina 20 - A.3 Bias

Product Overview11.0 PRODUCT OVERVIEWThe Liebert SiteLink-E® interface module is a BACnet router that provides the communications link between Liebert

Pagina 21

Installing the Liebert SiteLink-E Module22.0 INSTALLING THE LIEBERT SITELINK-E MODULEThe Liebert SiteLink-E module comes in an enclosure for mounting

Pagina 22

Installing the Liebert SiteLink-E Module3Figure 3 Enclosure dimensions—overallFigure 4 Enclosure dimensions—Wall mount14.25"(362mm)12"(304.8

Pagina 23

Installing the Liebert SiteLink-E Module4Figure 5 Enclosure dimensions—Floor mount16"(406.4mm)9"(228.6mm)0.88"(22.2mm)4.05"(102.8m

Pagina 24

Connect Input Power Wiring53.0 CONNECT INPUT POWER WIRING3.1 Power WiringThe Liebert SiteLink-E module is a Class 2 device (less than 30VAC, 0.4A). Ta